RANCANG BANGUN DAN PENGUJIAN ELEKTROKARDIOGRAF PORTABEL BERBASIS MIKROKONTROLER ESP8266, SENSOR AD8232, DAN DISPLAI MONITOR KOMPUTER

Danish Zaki Dhiyaulhaq, NIM.: 19106020021 (2023) RANCANG BANGUN DAN PENGUJIAN ELEKTROKARDIOGRAF PORTABEL BERBASIS MIKROKONTROLER ESP8266, SENSOR AD8232, DAN DISPLAI MONITOR KOMPUTER. Skripsi thesis, UIN SUNAN KALIJAGA YOGYAKARTA.

[img]
Preview
Text (RANCANG BANGUN DAN PENGUJIAN ELEKTROKARDIOGRAF PORTABEL BERBASIS MIKROKONTROLER ESP8266, SENSOR AD8232, DAN DISPLAI MONITOR KOMPUTER)
19106020021_BAB-I_IV-atau-V_DAFTAR-PUSTAKA.pdf - Published Version

Download (2MB) | Preview
[img] Text (RANCANG BANGUN DAN PENGUJIAN ELEKTROKARDIOGRAF PORTABEL BERBASIS MIKROKONTROLER ESP8266, SENSOR AD8232, DAN DISPLAI MONITOR KOMPUTER)
19106020021_BAB-II_sampai_SEBELUM-BAB-TERAKHIR.pdf - Published Version
Restricted to Registered users only

Download (5MB) | Request a copy

Abstract

This research is motivated by the lack of availability of electrocardiographs in Indonesian healthcare facilities. The aim of this study is to design, create, and test a portable electrocardiograph based on the ESP8266 microcontroller, AD8232 sensor, and computer monitor display. The research is conducted in three stages: design, fabrication, and system testing. The system is designed by creating the overall system design using Blender and circuit schematics using Fritzing. The fabrication stage involves creating the hardware and software components of the system, including the system blocks and casing. The software component consists of a display on WebSocket. The system is tested by determining accuracy and repeatability precision using the PQRST wave parameters. The designed system has been successfully created and tested. The test results show an accuracy of 0% for the amplitude of the P wave parameter, 66.079% for the amplitude of the QRS wave parameter, 81.699% for the amplitude of the T wave parameter, 0% for the QRS wave time interval parameter, 56.778% for the P-R time interval parameter, 77.485% for the Q-T time interval parameter, and 82.372% for the R-R time interval parameter. Additionally, the obtained precision values are 87.531% for the amplitude of the P wave parameter, 89.705% for the amplitude of the QRS wave parameter, 86.015% for the amplitude of the T wave parameter, 44.327% for the QRS wave time interval parameter, 60.380% for the P-R time interval parameter, 78.238% for the Q-T time interval parameter, and 78.449% for the R-R time interval parameter. The test results indicate that the system has not fully achieved accurate and consistent measurements for some parameters as per SNI IEC 60601-2-25 standards. The results of this research are expected to make a positive contribution to the field of telemedicine and improve accessibility for measurements in remote areas.

Item Type: Thesis (Skripsi)
Additional Information: Pembimbing: Frida Agung Rakhmadi, S.Si., M.Sc
Uncontrolled Keywords: Elektrokardiograf Portabel, ESP8266, AD8232, WebSocket
Subjects: Fisika
Divisions: Fakultas Sains dan Teknologi > Fisika (S1)
Depositing User: Muh Khabib, SIP.
Date Deposited: 19 Oct 2023 11:00
Last Modified: 19 Oct 2023 11:00
URI: http://digilib.uin-suka.ac.id/id/eprint/61484

Share this knowledge with your friends :

Actions (login required)

View Item View Item
Chat Kak Imum