Luky Agustiana, NIM.: 18106020052 (2025) RANCANG BANGUN ALAT UKUR TINGKAT STRES PADA MANUSIA MENGGUNAKAN SENSOR GALVANIC SKIN RESPONSE, SENSOR MAX30102, DAN SENSOR MLX90614 BERBASIS ARDUINO UNO. Skripsi thesis, UIN SUNAN KALIJAGA YOGYAKARTA.
|
Text (RANCANG BANGUN ALAT UKUR TINGKAT STRES PADA MANUSIA MENGGUNAKAN SENSOR GALVANIC SKIN RESPONSE, SENSOR MAX30102, DAN SENSOR MLX90614 BERBASIS ARDUINO UNO)
18106020052_BAB-I_IV-atau-V_DAFTAR-PUSTAKA.pdf - Published Version Download (2MB) | Preview |
|
![]() |
Text (RANCANG BANGUN ALAT UKUR TINGKAT STRES PADA MANUSIA MENGGUNAKAN SENSOR GALVANIC SKIN RESPONSE, SENSOR MAX30102, DAN SENSOR MLX90614 BERBASIS ARDUINO UNO)
18106020052_BAB-II_sampai_SEBELUM-BAB-TERAKHIR.pdf Restricted to Registered users only Download (4MB) | Request a copy |
Abstract
This research aims to design, manufacture, and test a stress level measuring instrument using the Galvanic Skin Response sensor, MAX 30102, Arduino-based MLX90614 Sensor. This research was conducted starting from designing, making, and testing stress level measuring instruments. The design of the stress level measuring instrument is done by making a software design using Lucidapp, and making a hardware design using the Tinkercad and Autodesk123 applications. The manufacturing stage is carried out by making the hardware and software of the stress level measuring instrument. Hardware manufacturing includes assembling components, making cases, and installing hardware. The software used in making the stress level measuring instrument program is Arduino IDE. Testing the stress level measuring instrument is done by finding the accuracy value and reproducibility precision of the stress level measuring instrument from the parameters of heart rate, body temperature, and skin moisture. The grouping of conditions in this study is divided into 4 conditions, namely: calm, relex, anxiety, and stress. The heart rate parameter of body temperature is compared with the vital sighn and thermogun measuring instruments while for the skin moisture parameter it is compared with other GSR sensors. The stress level measuring instrument has been successfully designed, made, and tested with an average accuracy value of 100% for skin moisture parameters, 98.96% for body temperature parameters, and 99.71% for heart rate parameters. The reproducibility precision value obtained is 100%, this result is based on the condition of the subject being measured. The results of this study are expected to make a positive contribution in the field of health, especially in monitoring a person's psychological health condition.
Item Type: | Thesis (Skripsi) |
---|---|
Additional Information / Supervisor: | Anis Yuniati, S.Si., M.Si., Ph.D. |
Uncontrolled Keywords: | detak jantung; galvanic skin response; kelembaban kulit; tingkat stres; suhu tubuh |
Subjects: | 500 Sains Murni > 530 Fisika |
Divisions: | Fakultas Sains dan Teknologi > Fisika (S1) |
Depositing User: | Muchti Nurhidaya [muchti.nurhidaya@uin-suka.ac.id] |
Date Deposited: | 21 Mar 2025 10:37 |
Last Modified: | 21 Mar 2025 10:37 |
URI: | http://digilib.uin-suka.ac.id/id/eprint/70556 |
Share this knowledge with your friends :
Actions (login required)
![]() |
View Item |