Salwa Nimaprilia, NIM.: 21101040007 (2025) THE LIGHTING SYSTEM ANALYSIS OF THE REFERENCE READING ROOM AT LIBRARY OF SUNAN KALIJAGA STATE ISLAMIC UNIVERSITY YOGYAKARTA. Skripsi thesis, UIN SUNAN KALIJAGA YOGYAKARTA.
|
Text (THE LIGHTING SYSTEM ANALYSIS OF THE REFERENCE READING ROOM AT LIBRARY OF SUNAN KALIJAGA STATE ISLAMIC UNIVERSITY YOGYAKARTA)
21101040007_BAB-I_IV-atau-V_DAFTAR-PUSTAKA.pdf - Published Version Download (2MB) | Preview |
|
|
Text (THE LIGHTING SYSTEM ANALYSIS OF THE REFERENCE READING ROOM AT LIBRARY OF SUNAN KALIJAGA STATE ISLAMIC UNIVERSITY YOGYAKARTA)
21101040007_BAB-II_sampai_SEBELUM-BAB-TERAKHIR.pdf - Published Version Restricted to Registered users only Download (3MB) | Request a copy |
Abstract
This study aims to determine and describe the lighting system of the reference reading room based on SNI 6197:2020 and library users perspective at Library of Sunan Kalijaga State Islamic University of Yogyakarta. This study uses a mixed method namely quantitative and qualitative method, the quantitative method in this research is calculating obtained data using a formula based on SNI 6197:2020, and qualitatife method will describing the results of lighting measurements actually and systematically based on users perspective. The subjects of this study were users who were registered as members of the Library, while the object of the study was the lighting system in the reference reading room of the UIN Sunan Kalijaga Yogyakarta Library building. The data collection method was carried out by means of observation, documentation, recording and measurement using a lighting measuring instrument, namely a lux meter. The data analysis stage starts from observation, lighting measurement using a luxmeter, then analyzing data and evaluation based on SNI 6197:2020. Based on the results of data analysis, the measurement of lighting intensity carried out in the library room in the morning, afternoon, and evening in the reference reading room on the second floor of the UIN Sunan Kalijaga Yogyakarta Library building has an average lighting level of 119.8 lux, and the overall lighting level Eaverage obtained is 84 lux, this is still far from the SNI 6197: 2020 standard, which is 350 lux. Meanwhile, the evaluation results from the user's perspective show that the lighting in the reference reading room is considered very good by users and librarians. The library needs to pay more attention to the lighting conditions in the reference room on the second floor of the library building with improvements to optimize lighting strength to meet the SNI 6197: 2020 standard regarding energy conservation in lighting systems.
| Item Type: | Thesis (Skripsi) |
|---|---|
| Additional Information / Supervisor: | Amalia Azka Rahmayani, M.Sc. |
| Uncontrolled Keywords: | Sistem Pencahayaan, SNI 6197:2020, Perpustakaan Perguruan Tinggi |
| Subjects: | 000 Ilmu Komputer, Ilmu Informasi, dan Karya Umum > 020 Ilmu Perpustakaan dan Informasi > 027.7 Perpustakaan Perguruan Tinggi dan Universitas |
| Divisions: | Fakultas Adab dan Ilmu Budaya > Ilmu Perpustakaan (S1) |
| Depositing User: | Muh Khabib, SIP. |
| Date Deposited: | 22 Apr 2026 14:05 |
| Last Modified: | 22 Apr 2026 14:05 |
| URI: | http://digilib.uin-suka.ac.id/id/eprint/76213 |
Share this knowledge with your friends :
Actions (login required)
![]() |
View Item |