PROTOTIPE SISTEM PERINGATAN DAN PEMADAM KEBAKARAN RUANGAN BERBASIS MIKROKONTROLLER ATMEGA16

KHABIB BAHRUL ULUM, NIM. 08650037 (2013) PROTOTIPE SISTEM PERINGATAN DAN PEMADAM KEBAKARAN RUANGAN BERBASIS MIKROKONTROLLER ATMEGA16. Skripsi thesis, UIN SUNAN KALIJAGA.

[img]
Preview
Text (PROTOTIPE SISTEM PERINGATAN DAN PEMADAM KEBAKARAN RUANGAN BERBASIS MIKROKONTROLLER ATMEGA16)
BAB I, VII, DAFTAR PUSTAKA.pdf

Download (481kB) | Preview
[img] Text (PROTOTIPE SISTEM PERINGATAN DAN PEMADAM KEBAKARAN RUANGAN BERBASIS MIKROKONTROLLER ATMEGA16)
BAB II, III, IV, V, VI.pdf
Restricted to Repository staff only

Download (1MB)

Abstract

Nowadays we often see the fires that occur in the community, handling of fire by the government also has not been able to minimize the losses. fires deplete the property in question will even claimed casualties when late in its handling. These losses can be minimized when there is an early notice to the person concerned and premature burnout fire that would hinder the growing fire extinguisher until the team came to the scene. Prototype warning system and fire-based microcontroller ATMega16 room built to assist communities in preventing the loss of life and minimize the losses caused by the fire room. The system will send an SMS alert when a sensor in the form of gas density and temperature reading room heat into the danger level. There are three ( 3) levels of danger are applied to the system. Level 1 works when the system is reading room temperature 41-49 ° C and 301-449 gas density, the system will send an SMS alert "Alert Fire". Level 2 works when the system is reading room temperature 51-59 °C and 451-599 gas density, the system will send an SMS alert "Alert Fire" and rang the buzzer. Level 3 works when the system is reading room temperature 61 - ~ °C and 601-1024 gas density, the system will send an SMS alert "Fire Watch", rang the buzzer and turn on the relay that is connected to the fire water pumps. Prototype warning system and applying fire-fighting gas sensor ( MQ-9) to detect smoke and temperature sensor ( LM35) to detect the temperature in the room. Of inferred functionality testing components connected with our prototype system is functioning properly. Inferred from usability testing prototype system is easy to use and can detect fires, but in providing SMS alert not working optimally. Keywords: Fire, Prototype ATmega16, temperature sensor ( LM35) , gas sensors ( MQ9) , SMS

Item Type: Thesis (Skripsi)
Subjects: Tehnik Informatika
Divisions: Fakultas Sains dan Teknologi > Teknik Informatika (S1)
Depositing User: Miftahul Ulum [IT Staff]
Date Deposited: 12 Jul 2013 15:44
Last Modified: 11 Mar 2016 08:23
URI: http://digilib.uin-suka.ac.id/id/eprint/8844

Share this knowledge with your friends :

Actions (login required)

View Item View Item
Chat Kak Imum